| Freq. (MHz) |
Nb elts |
Pitch (mm) |
Active lenght (mm) |
Active width (mm) |
Housing size *
(indicative value) |
10 |
32 |
0.3 |
9.6 |
8 |
17x14x35 |
10 |
64 |
0.25 |
16 |
10 |
24x16x35 |
10 |
128 |
0.25 |
32 |
10 |
40x18x40 |
5 |
16 |
0.6 |
9.6 |
8 |
17x14x35 |
5 |
32 |
0.5 |
16 |
12 |
24x18x40 |
5 |
64 |
0.5 |
32 |
15 |
40x20x40 |
5 |
128 |
0.5 |
64 |
15 |
75x22x45 |
2.25 |
32 |
1 |
32 |
20 |
40x26x35 |
2.25 |
64 |
1 |
64 |
20 |
75x26x35 |
2.25 |
128 |
1 |
128 |
20 |
140x28x40 |
General Characteristics
- Frequency from 500 kHz to 15 MHz
- Unlimited number of elements, typically 8 to 128
- High S/N ratio and optimized pulse length thanks to acoustic
matching to wedge material
- Reproducibility of the inspection through the homogeneity of
performance between the elements of the same probe, and between
different probes of the same type
- High reliability over time thanks to a robust, watertight design,
compatible with harsh industrial environments
Options
- Hard face for use in direct contact
- Integrated wedge
- Housing customized for the mechanical environment (inspected
parts, scanner, wedges, etc)
- Customized connection
- Adaptation to a particular environment (temperature, pressure,
radiation, chemical compatibility)
- Halogen-free for nuclear environments
- Water inlets
Accessories
|