TOFD
Transducers
Extra-flat TOFD for CRD* inspection
Application
Reactor vessel cover penetration tubes inspection
Principle
The extreme fineness of the probes, combined with
their curvature, allows them to be inserted between the control
bars and the guide tubes.
The transducers can thus inspect the guide tube in TOFD mode.
The orientation of the transducers enables longitudinal
or circumferential defects to be detected.
Advantages
Inspection feasibility, sensitivity, bandwidth
General Characteristics
These transducers are adapted individually to the
inspection constraints, and in particular to the handling, plating
and coupling mode.
- Thickness < 2.5mm (down to 1.5mm)
- Nominal frequency: 4 to 5MHz
- Adjustable PCS
- Refracted angle range: 45 to 70°
- Radius of curvature: 70mm (typical)
- Longitudinal or circumferential orientation
- Integrated cable
Options
- Water distribution device for the coupling
- Halogen-free
- Mechanical plating solution
- Steering
- Transducer at 0° for thickness measurement
|