Homepage    
  Site Map
  Jobs
  Contact us TOFD probes for NDT  
  Directions
 

Search Imasonic
Medical
Company
  Performance & Innovation
Projects specifications
Papers
Products
Immersion
Phased Array
T.O.F.D.
>> TO Series (standard)
Extra flat TOFD for CRD inspection
TOFD for tube inspection (inside)
Custom TOFD probes
 
Contact
Special
NDT Applications
Nuclear & power generation
Aeronautics
Metal Industry
Petrochemical
Transportation
Measurement
Application examples

 

TOFD Transducers

"Screw-in" standard TO series

General characteristics

  • IMASONIC piezocomposite technology
  • High sensitivity
  • Short pulse length
  • Designed for field conditions
  • Standard housing

Standard types

Transducers types
Recommended configurations
according to ENV583-6 standard
IMASONIC
reference
Nominal
frequency
(MHz)
Active
diameter
(mm)
Thickness < 70mm
Thickness 70-300 mm
Depth (mm)
Angle (°)
Depth (mm)
Angle (°)
TOF 2-12
2
12
30-70
45-60
100-300
45-60
TOF 3.5-6
3.5
6
30-70
45-60
30-100
45-60
TOF 5-3
5
3
10-30
50-60
<10
50-70
TOF 5-6
5
6
10-30
30-70
50-60
45-60
<10
10-30
50-70
45-60
TOF 5-12
5
12
30-70
45-60
30-100
45-60
TOF 7.5-6
7.5
6
10-30
50-60
<10
50-70
TOF 10-3
10
3
<10
10-30
50-70
50-60
<10
50-70
TOF 10-6
10
6
TOF 15-3
15
3
<10
50-70
-
-
TOF 20-3
20
3
-
-
-
-

Active diameter
(mm)
Housing type Housing
length
(mm)
Housing
diameter
(mm)
Thread
dimensions
(mm)
Connector
3-6 standard 30 9.5 M12 x 1.75 Lemo 00
3-6 short 20 9.5 M12 x 1.75 MCX
12 standard 29 17 M20 x 1.5 Lemo 00

Options

  • Integrated cable
  • High pressure resistance for offshore applications
  • Compatibility with oil and chemical agents
  • Compatibility with high temperature
  Top of this page
© 2002 Imasonic S.A.